Dialogic DSI SS7MD Uživatelský manuál Strana 71

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 176
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 70
71
Dialogic
®
DSI Signaling Server SGW Mode User Manual Issue 5
Example
CNTDS:DATE=2001-10-03,TIME=18:32:21,NTP=Y,OFFSET=+5:30;
EXECUTED
6.5.28 CNTDP – Configuration Time And Date Print
Synopsis
This command is used to print out the system date and time, whether NTP is active and to display the
OFFSET from UTC configured. See the CNTDS command for setting the time and date, UTC OFFSET and
activating NTP.
Syntax
CNTDP;
Prerequisites
None.
Attributes
None.
Example
CNTDP;
Configuration Time and Date
DATE TIME NTP OFFSET
2001-10-03 09:04:02 Y +5:30
6.5.29 CNTOS – Configuration Timeout Value Set
Synopsis
This command is used to change the value of a timer for a particular signaling system.
The user should specify the timer type (TTYPE), the timer itself (TO) and time to which it should be set,
expressed in either seconds (TSEC) or milliseconds (TMSEC).
Note: Some signaling system timer values are not changeable.
See the CNTOP command to verify timer values. See Section 5.3, “Signaling Gateway Timers” on page 46 for
the definition of signaling system specific timers.
Syntax
CNTOS:TTYPE=,TO=,{TSEC=|TMSEC=};
Prerequisites
None
Attributes
CONFIG
Examples
CNTOS:TTYPE=MTP3,TO=7,TSEC=30;