4 Message Reference
86
dest_slot
The destination slot references the CT Bus timeslot to which a local stream timeslot
can be connected or disconnected. The destination slot values are in the range 0 to
127.
pattern
The value of the fixed data to be generated. The value should be in the range 0 to 255.
Typical values are:
— 0x2a is the ITU-T idle pattern, and is appropriate for signaling (D)
channel.
— 0x55 is appropriate for A-law bearer channels (0x55 or 0xd5 are A-law
silence).
— 0xff is appropriate for µ-law bearer channels (0xff is µ-law silence).
4.3.10 MVD_MSG_SC_MULTI_CONNECT - CT Bus Multiple Connect
Request
Synopsis
Message sent to the board to control the switch to connect multiple paths through the
CT Bus switch.
Format
MVD_MSG_SC_MULTI_CONNECT (0x7e19)
May be used to request a confirmation.