Dialogic DSI SPCI Network Interface Boards Specifikace Strana 105

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 125
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 104
Dialogic
®
DSI SS7HD Network Interface Boards Programmer's Manual Issue 11
105
Value
Mnemonic
State
26
LIUS_BER5_CLRD
BER5 cleared
27
LIUS_BER3_OCRD
BER > 1 in 1,000
28
LIUS_BER3_CLRD
BER3 cleared
4.5.5 MGT_MSG_NTP_SYNC - Timestamping Resynchronization
Indication
Synopsis
Message sent if a significant time difference between the board and the host is
detected. This message is generated only if received message timestamping is
configured. See Section 3.5, “Received Message Timestamping” on page 41 for more
information.
Format
MESSAGE HEADER
Field Name
Meaning
type
MGT_MSG_NTP_SYNC (0x0f1d)
id
0
src
SP MGMT module ID
dst
0xef
rsp_req
0
hclass
0
status
0
err_info
0
len
8
PARAMETER AREA
Offset
Size
Name
0
4
int_sec
4
4
fr_sec
Description
The MGT_MSG_NTP_SYNC message is used to notify the host about step time updates.
Parameters
The MGT_MSG_NTP_SYNC message contains the following parameters:
int_sec
A 4-byte value containing the number of whole seconds in the time step indicated.
fr_sec
A 4-byte value containing the fraction of a second in the time step indicated.
Zobrazit stránku 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 124 125

Komentáře k této Příručce

Žádné komentáře