BROOKTROUT CONFIGURATION FILES
61
Configuration Parameters
for BRI Ports
multipoint circuit. Valid values are:
AUTO = Automatically detects the datalink setting
POINT2POINT = Configures for a point-to-point circuit
POINT2MULTIPOINT = Configures for a point-to-multipoint circuit
Default value: AUTO
default_caller_id_channel_0
or
default_caller_id_channel_1
Specifies a string of up to 15 characters that provides the caller ID to use
when placing outbound calls on channel 0 ( or 1). If the user application
provides a caller ID when placing a call, the system ignores this field.
Unit: character string
Range: 1 - 15 (_ECC_MAX_ANI_LENGTH)
Default value: Blank
did_offset
Specifies a value that defines the number of digits to remove from the beginning of
the string of DID digits received from the network. Valid values are:
0 = Does not remove any DID digits
1 - 63 = Specifies the number of digits to remove
Range: 0 through 63
Default value: 0
did_timeout
Specifies a value that defines the maximum timeout allowed before processing the
call after assuming receipt of the last DID digit. Valid values are:
0 = Indicates no waiting time
1 - 20 = Specifies the number of seconds to allow after receiving the last DID
digit before processing the call
Unit: second
Range: 0 through 20
Default value: 10 (used when the API does not find another value for this parameter)
disable_conn_ack
Specifies a Boolean value that determines whether the system sends a connection
acknowledgment after receiving a connect message from the network. Set the
parameter as follows:
FALSE = The system sends a connection acknowledgment message after
receiving a connect message from the network.
TRUE = The system does not send a connection acknowledgment message
after receiving a connect message from the network.
Default value: FALSE
emulation
Defines whether to configure the trunk for Central Office (CO) or Customer Premise
Equipment (CPE) protocol emulation. For testing purposes only. Valid values include:
CO = Emulates the CO protocol
CPE = Emulates the CPE protocol