Dialogic DSI SS7MD Uživatelský manuál Strana 125

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 191
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 124
125
Dialogic
®
DSI SS7MD Programmer’s Manual Issue 3
E1 interfaces have 32 timeslots numbered 0 to 31. Timeslot 0 is used for frame alignment and
timeslot 16 is generally used for signaling or is empty. Hence the normal configuration is to cross
connect timeslots 1 to 15 and 17 to 31 between the two ports on each signaling board by setting the
<ts_mask> value to 0xfffefffe.
T1/J1 interfaces have 24 timeslots, numbered 1 to 24. To cross connect all the timeslots on a T1
interface between the two PCM ports on a signaling board, the <ts_mask> value 0x1fffffe should be
used.
In duplex mode both PCM ports should have been previously configured under the same type of PCM
connector T1, E1 or J1.
<pattern>
For DSI SS7MD Boards, not applicable. Set to 0.
Zobrazit stránku 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 190 191

Komentáře k této Příručce

Žádné komentáře