6.9.3 MNINI – Maintenance Inhibit Initiate
Synopsis
This command initiates the inhibiting of SS7 signaling. When specified without the INH parameter, the C7
signaling link is deactivated and no further signaling is allowed. When specified with INHIBIT =Y, the SS7 link
inhibit message is sent over the signaling link.
Syntax
MNINI:C7LINK=…;
MNINI:C7LINK=,INHIBIT=Y;
Prerequisites
When specified without the INHIBIT parameter, the SS7 links have been initiated and are uninhibited.
Attributes
CONFIG, PROMPT
Examples
MNINI:C7LINK=5;
Output Format
Inhibiting C7LINK 23
Inhibiting C7LINK 31
EXECUTED
6.9.4 MNINE – Maintenance Inhibit End
Synopsis
This command ends the inhibiting of C7 links. The C7 link is activated and signaling is allowed to proceed.
When specified without the INHIBIT parameter, the C7 signaling link is activated and signaling is allowed to
proceed. When specified with INHIBIT =N, the SS7 link uninhibit message is sent over the signaling link.
Syntax
MNINE:C7LINK=…;
MNINE:C7LINK=,INHIBIT=N;
Prerequisites
When specified without the INHIBIT parameter, the SS7 links have been initiated and are inhibited.
Attributes
CONFIG
Examples
MNINE:C7LINK=5;
Output Format
Uninhibiting C7LINK 23
Uninhibiting C7LINK 31
EXECUTED